Electric Coil Systems - Features

  • ETL Listed to UL 1995
  • Up to 120,000 CFM
  • Open or Finned Tubular Coils
  • Single Point Power Options Available
  • Multiple Accessory and Control Options
  • Custom Configurations and Dimensions Available

Request

Quote

Electric Coil Unit

Standard Features

 

Construction

 

  • ETL Listed
  • Formed G-90 Galvanized base < 10,000 CFM
  • Primed welded structural steel base > 10,000 CFM
  • G-90 Galvanized Casing
  • Single wall access doors
  • Internally mounted motor, burner, and controls
  • Pre-wired, and factory tested
  • Single point power < xx KW
  • Two point power > xx KW
  • Sectioned units may require field assembly and wiring
  • Lifting provisions
  • Multiple configurations

 

Fan & Motor

 

  • DWDI forward curve industrial type blower(s)
  • Solid turned ground and polished shaft
  • Self aligning bearings
  • Premium E ODP blower motor with 1.15 service factor
  • Motor starter & overload protection
  • Adjustable motor base
  • Variable pitch drive up to 30 HP (Except when VFD is utilized)

 

Electric Coil

 

  • Open coil duct heater
  • Air proving safety switch
  • High temperature limit

 

Controls

 

  • Non-Fused door interlocked disconnect switch
  • Discharge air temperature control, with remote
  • set-point & summer-off-winter selector switch
  • Auxiliary contacts for exhaust fan interlock
  • Control voltage transformer

Optional Features

 

Construction

 

  • Double wall access doors with extruded aluminum frames (rated to 8" w.c.)
  • 1” 1.5#, 2” 1.5#, 2” 3#, 2" R-7.7, or
  • 2” R-13 insulation
  • G-90 galvanized, perforated G-90 galvanized, or stainless steel liner
  • Enamel, Epoxy, or Heresite coating
  • Stainless steel exterior construction
  • Custom configurations and dimensions
  • Built-in or separate chilled water or DX cooling coil module
  • Built-in or separate direct evaporative cooler module
  • Packaged DX cooling
  • Flat plate cell energy recovery section
  • Enthalpy wheel energy recovery section

 

Accessories

 

  • Mixing Box
  • Intake air hood w/ bird screen
  • Intake damper (standard or low leak)
  • Discharge damper (standard or low leak)
  • Discharge diffuser
  • Roof curb
  • Service platform
  • Service lights
  • GFI service outlet
  • V-Bank intake filter section
    • 1" or 2" Cleanable filters
    • Linked panel MERV-8 filters
    • 2" pleated MERV-8 filter
  • Flat bank final filter section
    • 2" Pleated MERV-8 filters
    • 4" Pleated MERV-11 to 14 filters
    • 12" Cartridge MERV-11 to 16 filters
    • Bag Filters MERV-9 to 14 filters
    • 12" Carbon odor control filters
    • 12" HEPA 99.97 to 99.99% filters

 

Fan & Motor

 

  • BIDW or AFDW Industrial centrifugal fan
  • BISW or AFSW Industrial centrifugal fan
  • Commercial or industrial plenum fan
  • Commercial or industrial plug fan
  • TEFC, Severe Duty or EXP Motors
  • AMCA A, B, or C Spark Resistant
  • Motor and bearings outside air stream
  • Spring or neoprene isolation

 

Electric Coil

 

  • Finned tubular duct heater
  • On/off economizer ductstat
  • Low temperature freezestat

 

Controls

 

  • Fused door interlocked disconnect switch
  • Room temperature control
  • Variable Air Volume
  • Supply fan VFD
  • DDC control system
  • PLC control system
  • Operation indication lights
  • Circuit analyzer indication lights
  • Clogged filter switch
  • Smoke detector

Electric Coil Systems -

Features

Electric Coil Unit

  • ETL Listed to UL 1995
  • Up to 120,000 CFM
  • Open or Finned Tubular Coils
  • Single Point Power Options Available
  • Multiple Accessory and Control Options
  • Custom Configurations and Dimensions Available

 

Request

Quote

  • ETL Listed to UL 1995
  • Up to 120,000 CFM
  • Open or Finned Tubular Coils
  • Single Point Power Options Available
  • Multiple Accessory and Control Options
  • Custom Configurations and Dimensions Available

 

Electric Coil Unit